Recommended Maintenance Procedure for the Mimaki JV3 Series

CAPPING STATION AND WIPER MAINTENANCE

1. DisWay Wash: located in the “Station menu” under “Maintenance.” Should be performed every 2-3 days to clean the waste line to prevent clogging.

HEAD AND WIPER MAINTENANCE

1. Carriage Out: located in the “Station menu” under “Maintenance.” Should be performed each morning, between large prints, between rolls, after the work day (if printing over night), and as needed.

2. Cleaning type [NORMAL]: press [test/cleaning] button located on the control panel twice.

AUTOMATIC CLEANING SETTINGS

1. Int Wiping: located in the “Maintenance” menu. The “scan count” setting should be set between 50-100 for text applications, and 20-50 for image applications (heavy coverage).

2. Sleep Clean: located in the “Maintenance” menu, should be set to [4 hours]. This setting will have the plotter automatically run a [NORMAL] cleaning every 4 hours.